18
ELECTRICAL WIRING
TO INSTALLER: INCOMING POWER MUST BE PO-
LARIZED. OBSERVE COLOR CODING.
DANGER
-- SHOCK HAZARD --
DISCONNECT ELECTRICAL POWER SUPPLY TO THE
UNIT BEFO RE SERVICING TO AVOID THE POSSIBIL-
ITY OF SHOCK INJUR Y OR DAMAGE TO THE EQUIP-
MENT.
CONNECT POWER SUPPL Y WIRES
a. Remove the field wiring cover.
b. Insert 115 volt wires through the large plastic bush-
ing on the left side of the furnace ( See Figure 16).
If conduit is used it should be secured to the control
box.
c. Connect the “hot wire to the BLACK pigtail lead,
and the “neutral” wire to the WHITE pigtail lead. Se-
cure all connections with suitable wire nuts and
wrap with electrical tape.
d. Connect the ground” wire to the grounding screw.
e. Reinstall the control panel cover and secure mount-
ing screw.
CONNECT THERMOST A T WIRES
a. Insert 24 volt wires through the small plastic bush-
ing just above the control panel.
b. Connect the thermostat wires to the furnace low
voltage pigtails (See Figure16).
c. Connect low--voltage circuit to the wall thermostat
pigtails.
A separate 120 V.A.C. supply circuit must be used for the
furnace. The circuit should be protected by a 15 amp fuse or
circuit breaker.
Figure 16
This screw does not
need to be remo ved in
order to remove the
field wiring co ver. ( ju st
loosen).
NOTE:
Cover should
not be removed
except when
servicing the
controls.
WALL THERMOSTAT
Avoid locations where the thermostat could be subject to
drafts from outside, or exposed to direct light from lamps,
sun, fireplaces, etc., or affected by air from a duct register
blowing directly on the thermostat.
The wall thermostat should be located 52 to 66 inches above
the floor. The preferred location is on an inside wall situated
in an area with good air circulation, and where the tempera-
ture will be reasonably representative of other living areas
the thermostat is controlling.